- Temperature setting range from -50°C to +10°C for specimen head
- Temperature setting range from -5°C to -35°C for the cutting blade
- Sectioning yield of 0.5µm to 500µm thick for trimming
- Sectioning yield of 0.5µm to 100µm thick for fine sectioning
- Editing capabilities for up to 15 active protocols
- User friendly environment for all programing needs with simultaneous performance.
- Two level circular basket design which saves bench top space
- Power supply strong enough to fluctuations w/ battery backup
- Fume control managed with carbon filters or vent adapter kit
- Four (4) mode operation: interval, single, multi, and continuous stroke with one knob.
- Digital backlight graphic display is great for indicating section thickness, cutting speed, section counting, and sample head position.
- Sectioning yield of 0.5µm to 500µm thick for trimming
- Sectioning yield of 0.5µm to 100µm thick for fine sectioning
- Gas diffusion process used when equipment is sensitive to moisture.
- Sterilizes and renders products free of viable microorganisms.
- Broadest sterilization method for medical products due to its effectiveness at low temperatures and its general compatibility with diverse materials.
- Wide dynamic range captures the entire range of data without saturation in a single, time-saving scan – no need for multiple scans
- Multiple Blot and Plate Scanning allows simultaneous scanning of multiple samples with varied intensities in one scan for increased convenience
- Two-Color Infrared and In-Gel western blots, Cell-Based Assays for In-Cell Western™ and On-Cell Western, Protein Detection for coomassie-Stained Gels
- Membrane and Slide Arrays, and In Vivo, Whole Organ, and Tissue Section with small animal imaging.
- The odyssey CLx is equipped with a field size of 25 cm x 25cm, laser lifetime of 40,000.00 working hours
- Key components: 700 and 800 laser light source, Scanning speed of 5-40 cm/s, resolution of 21-337 micrometers, Microscope focus range 0 mm – 4 mm, Operating environment is 15-35°C and dew point no greater than 20°.
- Available in four formats to suit your thermal cycling needs: 96-Well (0.2 or 0.1 mL), 384-Well, and 0.5 mL 60-Well.
- VeriFlex Blocks add control, giving you six independent temperature blocks to provide precise control over your PCR optimization.
- VeritiLink allows you to access the thermos cycler everywhere you go. (Up to 50 thermo cyclers monitored from your computer w/ real time email updates)
- 96 well plate design w/ use of fluorescent-based polymerase chain reaction (PCR) reagent.
- Quantitative detection of target nucleic acid sequences using real-time analysis
- Qualitative detection of targets using post-PCR analysis
- Qualitative analysis of the PCR product (achieved by melt curve analysis that occurs post-PCR).
- A patent-pending multi-mode (absorbance, fluorescence, luminescence) detector.
- Any wavelength can be used from the low UV to the near infrared.
- Equipped with a variable bandpass selection system, is ideal for spectral scanning applications.
- Additional read modes include: fluorescence polarization, time resolved fluorescence and AlphaScreen/AlphaLISA.